I2-10: DEWARS - SILVERED AND UNSILVERED

PURPOSE: To illustrate the function of silvering a dewar.

DESCRIPTION: Hot water is put into two dewars, one unsilvered and one silvered. The temperature of both in centigrade degrees is monitored as time passes:

t (min) silvered unsilvered

0 -- 84.5 -- 84.5

15 -- 83.5 -- 80.0

40 -- 83.0 -- 74.5

70 -- 82.0 -- 68.5

SUGGESTIONS:

REFERENCES: (PIRA 4B50.10)

EQUIPMENT: Two dewars in stands with cork stoppers, one silvered and one unsilvered, hot plate and water, digital thermometers

SETUP TIME: 10 min.